HOME PRODUCT Lightning Protection Intelligent Equipment Pre-storm 2.0 Atmospheric Electric Field Meter

PRODUCT

Pre-storm 2.0 Atmospheric Electric Field Meter
Pre-storm 2.0 Atmospheric Electric Field Meter Pre-storm 2.0 Atmospheric Electric Field Meter Pre-storm 2.0 Atmospheric Electric Field Meter

Pre-storm 2.0 Atmospheric Electric Field Meter

Product Attributes :

1. Pre-storm 2.0 atmospheric electric field meter adopts field-grinding disc principle. The motor drives rotor to rotate at constant speed to continuously measure atmospheric electric-field intensity and polarity changes for lightning early-warning.

2. It adopts inverted probe structure to resist bird droppings, rainwater and fallen-leaf interference. Aluminum alloy housing adapts to harsh outdoor conditions. It supports RS485 data output, 4G wireless transmission, local and cloud data processing with effective warning distance of 10-20km.

3. Widely deployed for meteorological observation, petrochemical sites, wind farms, scenic spots, golf courses and large outdoor amusement parks for thunderstorm lightning risk early warning.

 

Product Description

Working Principle

1. The equipment consists of stator (induction plate) and rotor (grounded shielding plate). The motor runs at 1560 rpm, alternately exposing and shielding the induction plate. Induced charges proportional to external electric-field strength are generated on stator.

2.Induced charge signal is converted into alternating current signal, amplified and filtered, then converted into voltage signal. After calibration, voltage value reflects atmospheric electric-field intensity and polarity.

3. Calculation formula Q (t)=-ε0ES (t). The external electric-field strength is obtained by measuring voltage generated by induced current passing through high-resistance component.
Pre-storm 2
Pre-storm 2
Pre-storm 2
Pre-storm 2
Pre-storm 2
Pre-storm 2

Product Features

1. Inverted probe design effectively blocks rainwater, bird droppings and fallen-leaf pollution; rugged aluminum shell for harsh outdoor environment. 
2. High measuring sensitivity 5 v/m, resolution 1 v/m, measuring error ≤5%, linearity ≤1%.
3. Support RS485 wired output and optional 2G/3G/4G wireless transmission module, data can be sent to multiple data-center stations simultaneously. 
4. Complete system includes acquisition software and business software, supports sound-image alarm when electric-field reaches warning threshold. 
5. Low power consumption, easy installation and maintenance, supports mains 220V or solar-battery hybrid power supply.
Pre-storm 2

Technical Parameters

1. Model: Prestorm 2.0 
2. Power supply: 24VDC; power consumption:<3W 
3. Sample rate:<5ms
4. Data interface: RS485, baud rate 19200 
5. Measuring range: ±300 kV/m 
6. Sensitivity:5 v/m; Resolution:1 v/m 
7. Measurement error: ≤5%; Linearity: ≤1%; Speed error: ≤1% 
8. Operating temperature:45℃~65℃ 
9. Effective lightning warning range:1020 km 
10. Probe installation type: inverted mounting 
11. Communication module: CCW4G01 4G wireless module, default IP 192.168.3.127

Application & Installation Notes

1. Application scenarios: lightning early warning for meteorological stations, petroleum-petrochemical facilities, wind-power plants, tourist attractions, golf courts and large outdoor amusement parks.

2. Installation requirement: install probe in clean pollution-free open-air area; stay away from lightning rods, static-prone surfaces and dust sources. Probe mounting height is 1.8m above ground on independent pillar or rooftop.

3. Foundation construction: build cement concrete foundation according to specification drawing, pre-embed M10 fixing screws and PVC threading pipe.

4. Wiring and debugging: connect 220V mains power cable and 4-core probe cable to control-box terminals; insert SIM card and connect antenna for CCW4G01 module; access web configuration page via browser to set site number, transmission cycle and server IP parameters.

5. Maintenance & calibration: power off before cleaning rotor and stator with soft brush and clean water. Perform on-site probe calibration after long-time operation or cleaning by using matching portable calibration equipment.