Product Attributes :

Pioneer LYESE E60 is the thirdgeneration early streamer emission air terminal developed by Guangzhou Leisidun Electrical Technology Development Co., Ltd. after fiveyear research and tests. It has passed domestic authoritative test and obtained multiple international certification certificates.

Upgraded with thirdgeneration core technology, it features stable and reliable performance, small deviation of advancestreamer parameters, fully complying with international standards. It delivers high lightningstriking accuracy, larger protection range and lower lightning current wavefront steepness.

 

 

Product Description

Working Principle

1. Based on traditional lightning air terminal, it adopts upgraded thirdgeneration active trigger system to generate highvoltage pulse signals. It creates continuous discharge path to meet the downward leader from thundercloud and divert lightning current into earth.

2. The device converts energy from ambient electrostatic and electromagnetic field into highvoltage signal, generating large quantities of ions at the needle tip to launch upward leader ahead of schedule.

3. The pregenerated upward leader connects with thundercloud downward leader at a distance away from the air terminal, which effectively expands the lightning protection radius.
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (1)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (2)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (3)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (4)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (5)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (6)

Product Features

1. Thirdgeneration upgraded core technology, stable and reliable performance, small parameter deviation after highvoltage lab tests and onsite measurement, fully meeting international standards.

2. Superior performance, high lightningstriking accuracy, larger protection range and lower lightning current wavefront steepness. Wellsuited for largearea distributed newenergy construction projects.

3. Collaborate with lightning online monitoring system to collect and transmit realtime operation data and lightning strike information, achieving cloudbased intelligent lightning protection solution.

4. Reliable structure, stainlesssteel SUS316L material, M16 threaded connection, maintenancefree and strong environmental adaptability.

Technical Parameters & Protection Scope

1. Advanced discharge time ΔT: 60μs. Protection radius is calculated according to French standard NFC17102:2011.
2. When effective mounting height h≥5m: Rp (h)=√(2rhh²+Δ(2r+Δ)); When 2m≤h≤5m: Rp=h×Rp (5)/5.
3. Rp refers to protection radius on target horizontal plane; h means height difference between needle tip and top of protected object; r equals 20m,30m,45m,60m corresponding to protection level IIV; ΔL=V×ΔT stands for upward advance distance.
4. Overall length:586mm; Needle diameter:16mm; Main rod diameter:20mm; Weight:2.5±0.1Kg; Material: SUS316L stainless steel; Connection type: M16 thread connection. Complete protection radius table is provided for different installation heights and protection grades.

Product Specifications

Pre-discharge Time △T 60 μs
Outline Dimension Length 586mm
Diameter of Air Terminal Rod 16mm
Diameter of Trigger Device 85mm
Diameter of Main Rod 20mm
Weight Kg 2.5±0.1
Material Stainless Steel SUS316L
Coupling Method Threaded M16

Protection range of Early Streamer Emission(ESE) lightning rod

PIONEER PLUS LY-ESE Early Streamer Emission Air Terminal Protection Radius Table(Rp)
Model Installation effective height h(m)
  2  3  4  5  6  8  10  15  20  25  30 
Level I(r=20m)
ESE3.0 32  47  63  79  79  79  79  80  80  80  79 
Level IⅡ(r=30m)
ESE3.0 34  52  69  86  86  87  88  89  89  90  90 
LevelⅢ(r=45m)
ESE3.0 39  58  78  97  97  98  99  101  102  103  104 
Level IV(r=60m)
ESE3.0 43  64  86  107  107  108  109  111  113  115  116 
size

Application

1. Especially applicable for lightning protection of distributed photovoltaic power stations, wind farms, largescale industrial plants, petrochemical facilities and sprawling newenergy projects.
2. Can be integrated with cloud computing platform, mobile phone terminal and PC terminal for remote data viewing and status monitoring. 
3. Match with special tester for routine inspection and onsite commissioning, supporting complete lightning protection and earthing system solution.

Product Certificate

certificate img (1)
certificate img (2)
certificate img (3)
certificate img (4)
certificate img (5)
certificate img (6)
certificate img (7)
certificate img (8)

Product Shipment

Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (2)
Pioneer LY-ESE E60 Early Streamer Emission Air Terminal (1)
搜同款
Online Inquiry